OLEDPLED And Solar Cell Application Ultra-clean Custom Glove Box

  • This glove box can provide an ultra clean enclosed environment, an effective pollution control solution, and improve product production efficiency.
  • Applied to metal, semiconductor, oxide and organic thin films, OLED, PLED, solar energy, etc.;providing multiple configurations and workstation sizes
  • Equipped with an evaporator; Equipped with a high-capacity purifier, the purity of H2O and O2 can reach below 1ppm; Top equipped with ultra clean purification system
  • During the static process, the cleanliness of the glove box can reach 10
  • Filtration particle size: 0.12 μ m
  •  High efficiency filters H13 to ultra high efficiency filters U15 grade
Availability:
Quantity:

Product Introduction

The OLED PLED and Solar Cell Application Ultra-clean Custom Glove Box is designed for advanced applications requiring pristine environments. This Vacuum Glove Box offers exceptional gas purification and contamination control, making it ideal for the production of OLEDs, PLEDs, and solar cells.


Product Advantage

This glove box features a Gas Purification system with a high-capacity purifier, achieving H2O and O2 levels below 1ppm. The ultra-clean purification system ensures a cleanliness level of 10 during static processes. The integrated evaporator, available in various configurations, maximizes efficiency in a compact design.


Technical Parameters

  • Filtration Particle Size: 0.12μm

  • Filter Efficiency: H13 to U15 grades

  • Purification Level: H2O and O2 < 1ppm

  • Integration Options: Evaporator on floor or side wall

  • Applications: Suitable for metal, semiconductor, oxidizing, and organic film


Product Uses

  • OLED Manufacturing: The glove box provides a controlled environment, ensuring that the materials used in OLEDs remain uncontaminated, enhancing the overall product quality and lifespan.

  • PLED Production: By maintaining a low oxygen and moisture environment, this glove box supports the efficient fabrication of PLEDs, promoting better electrical performance and stability.

  • Solar Cell Development: The ultra-clean conditions facilitate the development of solar cells, reducing defects and increasing energy conversion efficiency.


Product Operate Guide

  1. Ensure all connections, including the vacuum pump, are securely attached before operation.

  2. Activate the gas purification system and monitor levels using the Dew Point Analyzer and Oxygen Analyzer.

  3. Maintain a constant vacuum and check filtration systems regularly for optimal performance.


FAQ

Q: What types of applications is this glove box suitable for?
A: It is designed for OLED, PLED, solar cell production, and other applications requiring a clean environment.

Q: How does the gas purification system work?
A: The high-capacity purifier effectively reduces H2O and O2 levels, ensuring optimal conditions for sensitive materials.

Q: What are the filtration capabilities?
A: The glove box features filters with a particle size of 0.12μm, offering high efficiency for contamination control.

Related News
19 / 05 / 2026
OLED And Solar Cell Glove Box: Evaporator Integration System

Optimize OLED & solar cell production with integrated evaporator glove boxes. Maintain <1ppm O2/H2O for high-efficiency, repeatable thin-film devices.

Read More
20 / 05 / 2026
Glove Box For OLED Manufacturing: Inert Atmosphere Solutions

Optimize OLED yields with inert glove boxes. Maintain <1ppm H2O/O2 via advanced purification, tool integration, and effective solvent management.

Read More
16 / 05 / 2026
Vacuum Glove Box For Battery Research: Complete Selection Guide

Optimize battery R&D with high-purity glove boxes. Ensure <1ppm H2O/O2, ISO compliance, and safety for lithium and solid-state battery research.

Read More
17 / 05 / 2026
Welding Glove Box: High Purity Environment For TIG And Laser Welding

Guide to specifying inert welding glove boxes. Learn to achieve ≤ 1 ppm purity for defect-free TIG and laser welding of reactive aerospace alloys.

Read More
18 / 05 / 2026
Super Capacitor Glove Box: Automated Assembly Line For Battery Production

Technical guide to automated battery assembly: maintain <1ppm H2O/O2 with integrated glove box systems to eliminate contamination and maximize yield.

Read More
18 / 02 / 2026
How To Choose The Right Glove Box for Battery Research: A Complete Guide?

Yesterday your electrode coating looked perfect. Today the electrochemical performance shifts, impedance increases, and the results are inconsistent.

Read More
Get in Touch

Quick Links

Support

Product Category

Contact Us

  Add: No. 111 Tingyi Road, Tinglin Town, Jinshan District, Shanghai 201505,P.R.China
  Tel: +86 13600040923
  Email: sales.lib@mikrouna.com
Copyright © 2024 Mikrouna (Shanghai) Industrial Intelligent Technology Co., Ltd. All Rights Reserved. Sitemap