+86 13600040923        sales.lib@mikrouna.com
You are here: Home / Products / Custom Glove Box / Glove Box for Super Capacitor Assembly with O₂ & Temperature Control

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Glove Box for Super Capacitor Assembly with O₂ & Temperature Control

  • This production line can be used for the production of super capacitors and lithium batteries
  • Mobile oven: maximum temperature of 200 ° C
  • The dedicated docking system between the oven and the front compartment can prevent any exposure to ambient air
  •  Fully automatic system: The oven, cooling chamber (which can reduce energy consumption and improve productivity), glove box and discharge chamber are all fully automated for transmission
  • Sequential use of one glove box and multiple ovens: cost saving and suitable for small batch production
Availability:
Quantity:
  • Mikrouna

The Super Capacitor Glove Box is an advanced solution designed for the production of super capacitors and lithium batteries. This cutting-edge device features temperature control and an integrated oxygen monitor, ensuring optimal conditions for sensitive materials. Its exclusive docking system guarantees no exposure to ambient air during processing.


Product Advantage

This Vacuum Glove Box is equipped with a vacuum pump and organic solvent adsorber for effective gas purification and solvent purification. The cooled antechamber significantly reduces energy consumption while enhancing efficiency. With its ability to operate multiple ovens sequentially, it offers cost-effective solutions for small batches of various samples.


Technical Parameters

  • Maximum Temperature: 200°C

  • Oxygen Monitor: Integrated for real-time monitoring

  • Vacuum Pump: High-efficiency model

  • Dew Point Analyzer: Ensures optimal moisture control

  • Oxygen Analyzer: Monitors oxygen levels continuously


Product Uses

Ideal for lithium battery research, the Super Capacitor Glove Box supports various applications, including the production of super capacitors and other sensitive materials that require controlled environments.


Product Operate Guide

  1. Ensure the vacuum glove box is properly sealed before initiating the process.

  2. Set the desired temperature on the movable oven.

  3. Use the dew point analyzer to monitor humidity levels.

  4. Regularly check the oxygen analyzer for optimal gas conditions.

  5. Follow automated transfer protocols between the glove box and ovens.


FAQ

Q: What materials can be processed in the glove box?
A: The glove box is suitable for various organic solvents and materials used in battery production.

Q: How does the gas purification work?
A: The system uses advanced filtration techniques to remove impurities from the working environment.

Q: Can the glove box be used for large-scale production?
A: While designed for small batches, it can efficiently handle multiple samples in sequence, offering flexibility for varying production needs.

Related News
13 / 11 / 2026
Can Vacuum Glove Boxes Be Customized to Non-Standard Dimensions?

Most leading professional glove box manufacturers offer non-standard customization services. Equipment manufacturers such as Mikrouna have comprehensive capabilities in custom design, manufacturing, and assembly. Based on customers' actual operating requirements, they can provide tailored designs for the glove box enclosure, transfer chambers, and workstation layouts.

Read More
13 / 11 / 2026
What Leakage Rate Can a Vacuum Glove Box Achieve?

The leakage rate represents the percentage of the glove box's total internal volume that is infiltrated by external air per hour. It is generally expressed in vol%/h. The lower the leakage rate, the better the airtightness of the glove box, making it easier to maintain consistently low oxygen and moisture levels inside the chamber over extended periods.

Read More
09 / 11 / 2026
Mikrouna Tutorial: Quick Glove Box Glove Replacement (Non-Stop Operation)

This tutorial demonstrates the non-stop procedure for quickly replacing glove box gloves from Mikrouna. Long-term frequent use in university testing, lithium battery R&D and new material synthesis often causes glove aging, cracking and air leakage, which can let water and oxygen in and ruin sensitive samples. Follow the two-step method to swap gloves safely under positive pressure without shutting down the glove box system. Critical post-replacement checks and purging requirements are also covered to keep H₂O and O₂ indicators stable and protect your experiments.

Read More
04 / 11 / 2026
Precautions for Re‑commissioning a Glove Box after Long‑Term Idleness

As critical equipment for anhydrous and oxygen‑free experiments, a glove box is prone to sealing‑element aging, vacuum‑pump oil deterioration, water‑oxygen sensor drift and other faults after prolonged shutdown. Direct operation under such conditions is not permitted.

Read More
04 / 11 / 2026
Materials Processable in Vacuum Glove Boxes

A vacuum glove box, also known as an inert‑gas glove box, creates an anhydrous and oxygen‑free operating environment with low moisture and low oxygen levels through a sealed chamber and vacuum transfer antechamber. It serves as core equipment for scientific research, lithium‑ion battery, semiconductor and new‑material industries. Many customers wonder during model selection: what materials can be processed in a vacuum glove box? Which materials are strictly prohibited from being placed inside the box?

Read More
16 / 10 / 2026
How Can A Vacuum Glove Box Maintain Moisture And Oxygen Below 1 Ppm?

In lithium battery, perovskite, nuclear-industry, and OLED research and production, a vacuum glove box may be designed to maintain internal moisture and oxygen levels below 1 ppm. This performance depends on five systems working together in a closed control loop: sealing protection, purification columns, gas circulation, online moisture and oxygen monitoring, and PLC-based automatic control.

Read More
Get in Touch

Quick Links

Support

Product Category

Contact Us

  Add: No. 111 Tingyi Road, Tinglin Town, Jinshan District, Shanghai 201505,P.R.China
  Tel: +86 13600040923
  Email: sales.lib@mikrouna.com
Copyright © 2024 Mikrouna (Shanghai) Industrial Intelligent Technology Co., Ltd. All Rights Reserved. Sitemap