Advanced Glove Box Laboratory Glove Box Nitrogen Glove Box

  • Advanced glove box with dual purifier is commonly used in full-scale production
  •  Large capacity purification system: capable of adsorbing 60 liters of oxygen and absorbing 2000 grams of water, thereby extending the time between regeneration cycles.
  •  Equipped with 2 purifiers: when one is regenerated, the system automatically switches to the other to achieve continuous production.
  • From a single workstation system to a multi workstation system: can be operated side by side or face-to-face with an integrated gas purification system (2 switchable purifiers), PLC controller and HMI; equipped with sealed box, internal and external transmission front chamber, tilting operation side with replaceable sight glass and vacuum pump, etc; the purity of the glove box can reach H2O<1ppm and O2<1ppm.
Availability:
Quantity:
  • Advanced(3660/750/900)

  • Mikrouna

From Single to Multiple workstation systems, to be operated either side by-side or face to face with integrated Gas purification system (2 switchable Purifier), PLC controller and HMI, incl. sealed box, in and outward transfer antechamber, inclined operation sides with replaceable sight glass and vacuum pump etc. Attainable purity of the glovebox is H2O<1ppm, O2<1ppm.


This system includes a large capacity purification system capable of adsorbing 60l of O2 and absorbing 2000g of moisture extending your time between regeneration cycles.


Features

Closed Loop Gas Circulation
Inert gas in a closed loop. The gas is circulated by the blower and purifier, H2O, O2 can be removed continuously.


Auto Purging
The replacement of the atmosphere inside the glove box can be achieved automatically by the purging valves.


Automatic Regeneration
H2O and O2 removal material can be regenerated. The regeneration process can be program controlled.


Automatic Pressure Control
The pressure in the glove box is controlled automatically by the Programmable Logic Controller (PLC). Working pressure can be set either between +15mba and -15mba or between +12 mbar and -12 mbar. If the pressure goes over the set range, the system will be protected automatically.


Eco Mode
The vacuum pump will be activated automatically when necessary, and will turn off after a period of idle time. Blower frequency will be switched to 25Hz when moisture and oxygen level reaches to less than 1 ppm


Specifications

Main Chamber Dimensions
Modular length: 1220mm/1500mm/1800mm/2440mm ( 48.0”/59.1”/70.9”/ 96.0”)
Modular depth: 750mm/1000mm/1200mm (29.5”/39.4”/47.2”)
Modular height: 900m( 35.4”)
Material: Stainless steel type 304, thickness 3mm (1/8”)
Sight Windows: Inclined, Safety Glass, thickness 8mm (1/3”)
Gloves Ports: POM (Polyoxymethylene), 220mm (8.7”) Diameter
Gloves: 8B1532
Dust Filter: HEPA 0.3μ, one gas inlet, one gas outlet
Shelving: Stainless Steel, two fixed shelves (adjustable shelves available)
Lighting: External LED lights, front mounted above sight glass.
Feedthroughs: One power feedthrough, 3 blind-flanges


Large Antechamber
Diameter: 360mm (14.2”) or 400mm (15.7”), Length 600mm (23.6”)
With Sliding tray
Spindle lock door, Vertical operation with lifting mechanism
Automatic operation via solenoid valves


Small Antechamber
Diameter 150 mm (5.9”) or 100mm (3.9”), Length 300mm(11.8”)
Hinged door
Manual operation via hand valve


Dual Purifier
Removal of H2O and O2  to Less than 1 ppm moisture and oxygen
Absorber Unit: 5kg Copper catalyst,5kg Molecular sieve
Capacity to remove oxygen, 60L , moisture 2000g.
Encapsulated Blower: 90m3/h
Regeneration: PLC control all process including heating, introducing mix gas (working gas mixed with Hydrogen 5-10%), etc.


System Control
PLC and HMI: Siemens S7


Vacuum Pump
8m3/h Rotary vane pump with oil mist filter and gas ballast

Options&Accessories

Accessories Options
Moisture Sensor
Oxygen Sensor
Solvent Absorber
Heated Antechamber
Refrigerator
Cold Well
Microscope Unit
Ionizer without fan
Various Feedthroughs


Other Options
Customized box sizes
Integrating  customer’s instruments into the glovebox, like evaporator, ALD System and Spin Coater etc.
Polycarbonate Window(s)
Quick Release Window(s)
Antechamber with interlocking door
Small chamber with sliding tray
Antechamber purging  only without vacuum
Antechamber refilling from Gas cylinder instead of box
Rectangular Antechamber
Flexible shelves – adjustable up & down – adjustable back & forth
12m3/h Rotary pump
Dry scroll pump
Prompt service


Advantages

High Capacity Purifier
Rapid removal of H2O and O2 to less than 1ppm
Long intervals between regeneration cycles.


PLC Control and Color Touchscreen HMI
Automatic Purge; Circulation; Regeneration; Pressure control; User Friendly Interface.


Long Life Moisture and Oxygen Analyzers
P2O5 Moisture Sensor: Corrosion resistant, Renewable by acid-cleaning if the probe is contaminated by HF or other corrosive environmental exposure.
ZrO2 Oxygen Sensor: Solid sensor, long life, can be exposed to air without consumption.


Customize a glove box specially for your application
Our engineering team can help to turn your idea into a solution.


Stainess Steel gas pipes and connectors
All the gloveboxes has been upgrade to stainless steel pipes and connectors with much higher corrosive-proof for highly corrosive environment.

Related News
14 / 08 / 2025
Can You Make Lithium-ion Battery in Nitrogen Glove Box

Lithium-ion batteries power a vast range of devices, from smartphones, laptops, and power tools to electric vehicles and renewable energy storage systems. Their high energy density, long cycle life, and rechargeability have made them one of the most important energy storage technologies of our time. However, producing lithium-ion batteries is not as simple as assembling a few components.

Read More
18 / 08 / 2025
What Are The Critical Measurements Needed in Inert Glove Boxes?

A nitrogen glove box is a specialized sealed enclosure designed to provide an inert atmosphere for handling sensitive materials. These systems are widely used in laboratories and industrial applications to protect products from exposure to oxygen, moisture, or other contaminants. Maintaining precise control of internal conditions is essential to ensure both the safety of the operator and the integrity of the materials being handled.

Read More
20 / 08 / 2025
Why The Glove Box Needs Nitrogen Or Other Inert Gas Protection

Certain scientific and industrial experiments require environments free from oxygen, moisture, dust, and other contaminants to protect both the materials and the people conducting the work. In these sensitive and often hazardous processes, maintaining a controlled atmosphere is not just a convenience but an absolute necessity. Glove boxes provide a sealed, safe, and clean workspace where these conditions can be precisely regulated.

Read More
08 / 09 / 2025
How The Glove Box's Internal Atmosphere Control Function Works

In modern scientific research and industrial processes, the glove box plays an indispensable role. A glove box provides a sealed and controlled environment that isolates sensitive experiments from exposure to oxygen, moisture, dust, and other contaminants.

Read More
05 / 09 / 2025
The Role of Glove Boxes in Lithium Battery Manufacturing

Against the backdrop of rapid development of new energy vehicles, energy storage systems, and consumer electronics, lithium batteries, as important energy carriers, have high requirements for material stability, environmental sensitivity, and safety in their manufacturing processes. Glove boxes, wit

Read More
03 / 09 / 2025
How To Deal with The High Water And Oxygen Content in The Glove Box After Regeneration?

As a widely used experimental equipment in many fields, the control of water and oxygen content inside the glove box is crucial. When the water and oxygen content in the glove box remains high after regeneration, it not only affects the accuracy and success rate of the experiment, but may also cause

Read More
Get in Touch

Quick Links

Support

Product Category

Contact Us

  Add: No. 111 Tingyi Road, Tinglin Town, Jinshan District, Shanghai 201505,P.R.China
  Tel: +86 13600040923
  Email: sales.lib@mikrouna.com
Copyright © 2024 Mikrouna (Shanghai) Industrial Intelligent Technology Co., Ltd. All Rights Reserved. Sitemap