+86 13600040923        sales.lib@mikrouna.com
You are here: Home / Products / Glove Box / Advanced Glove Box Laboratory Glove Box Nitrogen Glove Box

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Advanced Glove Box Laboratory Glove Box Nitrogen Glove Box

  • Advanced glove box with dual purifier is commonly used in full-scale production
  •  Large capacity purification system: capable of adsorbing 60 liters of oxygen and absorbing 2000 grams of water, thereby extending the time between regeneration cycles.
  •  Equipped with 2 purifiers: when one is regenerated, the system automatically switches to the other to achieve continuous production.
  • From a single workstation system to a multi workstation system: can be operated side by side or face-to-face with an integrated gas purification system (2 switchable purifiers), PLC controller and HMI; equipped with sealed box, internal and external transmission front chamber, tilting operation side with replaceable sight glass and vacuum pump, etc; the purity of the glove box can reach H2O<1ppm and O2<1ppm.
Availability:
Quantity:
  • Advanced(3660/750/900)

  • Mikrouna

From Single to Multiple workstation systems, to be operated either side by-side or face to face with integrated Gas purification system (2 switchable Purifier), PLC controller and HMI, incl. sealed box, in and outward transfer antechamber, inclined operation sides with replaceable sight glass and vacuum pump etc. Attainable purity of the glovebox is H2O<1ppm, O2<1ppm.


This system includes a large capacity purification system capable of adsorbing 60l of O2 and absorbing 2000g of moisture extending your time between regeneration cycles.


Features

Closed Loop Gas Circulation
Inert gas in a closed loop. The gas is circulated by the blower and purifier, H2O, O2 can be removed continuously.


Auto Purging
The replacement of the atmosphere inside the glove box can be achieved automatically by the purging valves.


Automatic Regeneration
H2O and O2 removal material can be regenerated. The regeneration process can be program controlled.


Automatic Pressure Control
The pressure in the glove box is controlled automatically by the Programmable Logic Controller (PLC). Working pressure can be set either between +15mba and -15mba or between +12 mbar and -12 mbar. If the pressure goes over the set range, the system will be protected automatically.


Eco Mode
The vacuum pump will be activated automatically when necessary, and will turn off after a period of idle time. Blower frequency will be switched to 25Hz when moisture and oxygen level reaches to less than 1 ppm


Specifications

Main Chamber Dimensions
Modular length: 1220mm/1500mm/1800mm/2440mm ( 48.0”/59.1”/70.9”/ 96.0”)
Modular depth: 750mm/1000mm/1200mm (29.5”/39.4”/47.2”)
Modular height: 900m( 35.4”)
Material: Stainless steel type 304, thickness 3mm (1/8”)
Sight Windows: Inclined, Safety Glass, thickness 8mm (1/3”)
Gloves Ports: POM (Polyoxymethylene), 220mm (8.7”) Diameter
Gloves: 8B1532
Dust Filter: HEPA 0.3μ, one gas inlet, one gas outlet
Shelving: Stainless Steel, two fixed shelves (adjustable shelves available)
Lighting: External LED lights, front mounted above sight glass.
Feedthroughs: One power feedthrough, 3 blind-flanges


Large Antechamber
Diameter: 360mm (14.2”) or 400mm (15.7”), Length 600mm (23.6”)
With Sliding tray
Spindle lock door, Vertical operation with lifting mechanism
Automatic operation via solenoid valves


Small Antechamber
Diameter 150 mm (5.9”) or 100mm (3.9”), Length 300mm(11.8”)
Hinged door
Manual operation via hand valve


Dual Purifier
Removal of H2O and O2  to Less than 1 ppm moisture and oxygen
Absorber Unit: 5kg Copper catalyst,5kg Molecular sieve
Capacity to remove oxygen, 60L , moisture 2000g.
Encapsulated Blower: 90m3/h
Regeneration: PLC control all process including heating, introducing mix gas (working gas mixed with Hydrogen 5-10%), etc.


System Control
PLC and HMI: Siemens S7


Vacuum Pump
8m3/h Rotary vane pump with oil mist filter and gas ballast

Options&Accessories

Accessories Options
Moisture Sensor
Oxygen Sensor
Solvent Absorber
Heated Antechamber
Refrigerator
Cold Well
Microscope Unit
Ionizer without fan
Various Feedthroughs


Other Options
Customized box sizes
Integrating  customer’s instruments into the glovebox, like evaporator, ALD System and Spin Coater etc.
Polycarbonate Window(s)
Quick Release Window(s)
Antechamber with interlocking door
Small chamber with sliding tray
Antechamber purging  only without vacuum
Antechamber refilling from Gas cylinder instead of box
Rectangular Antechamber
Flexible shelves – adjustable up & down – adjustable back & forth
12m3/h Rotary pump
Dry scroll pump
Prompt service


Advantages

High Capacity Purifier
Rapid removal of H2O and O2 to less than 1ppm
Long intervals between regeneration cycles.


PLC Control and Color Touchscreen HMI
Automatic Purge; Circulation; Regeneration; Pressure control; User Friendly Interface.


Long Life Moisture and Oxygen Analyzers
P2O5 Moisture Sensor: Corrosion resistant, Renewable by acid-cleaning if the probe is contaminated by HF or other corrosive environmental exposure.
ZrO2 Oxygen Sensor: Solid sensor, long life, can be exposed to air without consumption.


Customize a glove box specially for your application
Our engineering team can help to turn your idea into a solution.


Stainess Steel gas pipes and connectors
All the gloveboxes has been upgrade to stainless steel pipes and connectors with much higher corrosive-proof for highly corrosive environment.

Related News
08 / 05 / 2025
What Equipment Is Configured Inside A Glove box? Detailed Explanation of Filters, Shelving Units, And More

As a high-tech laboratory apparatus, a glovebox is equipped with a variety of internal components, each serving distinct functions to ensure a stable, reliable, and efficient working environment. This article provides a detailed analysis of the primary equipment inside a glovebox—such as filters, sh

Read More
07 / 05 / 2025
Oxygen And Moisture Removal Capacities of Glove Box Purification Columns

In fields such as scientific research, healthcare, electronics manufacturing, and advanced material development, the glove box serves as a critical environmental control device. The purity of its internal atmosphere is vital for experimental outcomes and production quality. The purification column w

Read More
06 / 05 / 2025
What Is The Maximum Temperature of The Heating Chamber in The Glove box Welding Series?

In high-tech manufacturing, particularly in precision welding processes, environmental control is critical to ensuring product quality and performance. The glovebox welding series, designed specifically for welding applications, relies heavily on its integrated heating chamber for temperature regula

Read More
30 / 04 / 2025
What Is The Price Range of Glove Boxes? Do Prices Vary Significantly Across Brands And Models?

As critical equipment in scientific research, medical, and industrial production fields, the pricing of glove boxes is influenced by multiple factors, including brand, model, specifications, manufacturing processes, materials, and technical sophistication. Consequently, glove boxes exhibit a relativ

Read More
28 / 04 / 2025
How Does the Gas Purification System in a Glove Box Work? What Purification Materials Are Used?

As a highly sealed experimental apparatus, glove boxes are widely utilized in scientific research, industrial production, and other fields, particularly in scenarios requiring stringent environmental control. One of their core functions lies in the gas purification system, which maintains internal g

Read More
29 / 04 / 2025
Choose A Scientific Research Glove Box Suitable for The Laboratory

When setting up a laboratory, selecting the right equipment is crucial to ensure the success and efficiency of scientific experiments. One of the most important pieces of equipment in many research labs is the scientific research glove box.

Read More
Get in Touch

Quick Links

Support

Product Category

Contact Us

  Add: No. 111 Tingyi Road, Tinglin Town, Jinshan District, Shanghai 201505,P.R.China
  Tel: +86 13600040923
  Email: sales.lib@mikrouna.com
Copyright © 2024 Mikrouna (Shanghai) Industrial Intelligent Technology Co., Ltd. All Rights Reserved. Sitemap