+86 13600040923        sales.lib@mikrouna.com
You are here: Home / Products / Glove Box / Advanced Glove Box Laboratory Glove Box Nitrogen Glove Box

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Advanced Glove Box Laboratory Glove Box Nitrogen Glove Box

  • Advanced glove box with dual purifier is commonly used in full-scale production
  •  Large capacity purification system: capable of adsorbing 60 liters of oxygen and absorbing 2000 grams of water, thereby extending the time between regeneration cycles.
  •  Equipped with 2 purifiers: when one is regenerated, the system automatically switches to the other to achieve continuous production.
  • From a single workstation system to a multi workstation system: can be operated side by side or face-to-face with an integrated gas purification system (2 switchable purifiers), PLC controller and HMI; equipped with sealed box, internal and external transmission front chamber, tilting operation side with replaceable sight glass and vacuum pump, etc; the purity of the glove box can reach H2O<1ppm and O2<1ppm.
Availability:
Quantity:
  • Advanced(3660/750/900)

  • Mikrouna

From Single to Multiple workstation systems, to be operated either side by-side or face to face with integrated Gas purification system (2 switchable Purifier), PLC controller and HMI, incl. sealed box, in and outward transfer antechamber, inclined operation sides with replaceable sight glass and vacuum pump etc. Attainable purity of the glovebox is H2O<1ppm, O2<1ppm.


This system includes a large capacity purification system capable of adsorbing 60l of O2 and absorbing 2000g of moisture extending your time between regeneration cycles.


Features

Closed Loop Gas Circulation
Inert gas in a closed loop. The gas is circulated by the blower and purifier, H2O, O2 can be removed continuously.


Auto Purging
The replacement of the atmosphere inside the glove box can be achieved automatically by the purging valves.


Automatic Regeneration
H2O and O2 removal material can be regenerated. The regeneration process can be program controlled.


Automatic Pressure Control
The pressure in the glove box is controlled automatically by the Programmable Logic Controller (PLC). Working pressure can be set either between +15mba and -15mba or between +12 mbar and -12 mbar. If the pressure goes over the set range, the system will be protected automatically.


Eco Mode
The vacuum pump will be activated automatically when necessary, and will turn off after a period of idle time. Blower frequency will be switched to 25Hz when moisture and oxygen level reaches to less than 1 ppm


Specifications

Main Chamber Dimensions
Modular length: 1220mm/1500mm/1800mm/2440mm ( 48.0”/59.1”/70.9”/ 96.0”)
Modular depth: 750mm/1000mm/1200mm (29.5”/39.4”/47.2”)
Modular height: 900m( 35.4”)
Material: Stainless steel type 304, thickness 3mm (1/8”)
Sight Windows: Inclined, Safety Glass, thickness 8mm (1/3”)
Gloves Ports: POM (Polyoxymethylene), 220mm (8.7”) Diameter
Gloves: 8B1532
Dust Filter: HEPA 0.3μ, one gas inlet, one gas outlet
Shelving: Stainless Steel, two fixed shelves (adjustable shelves available)
Lighting: External LED lights, front mounted above sight glass.
Feedthroughs: One power feedthrough, 3 blind-flanges


Large Antechamber
Diameter: 360mm (14.2”) or 400mm (15.7”), Length 600mm (23.6”)
With Sliding tray
Spindle lock door, Vertical operation with lifting mechanism
Automatic operation via solenoid valves


Small Antechamber
Diameter 150 mm (5.9”) or 100mm (3.9”), Length 300mm(11.8”)
Hinged door
Manual operation via hand valve


Dual Purifier
Removal of H2O and O2  to Less than 1 ppm moisture and oxygen
Absorber Unit: 5kg Copper catalyst,5kg Molecular sieve
Capacity to remove oxygen, 60L , moisture 2000g.
Encapsulated Blower: 90m3/h
Regeneration: PLC control all process including heating, introducing mix gas (working gas mixed with Hydrogen 5-10%), etc.


System Control
PLC and HMI: Siemens S7


Vacuum Pump
8m3/h Rotary vane pump with oil mist filter and gas ballast

Options&Accessories

Accessories Options
Moisture Sensor
Oxygen Sensor
Solvent Absorber
Heated Antechamber
Refrigerator
Cold Well
Microscope Unit
Ionizer without fan
Various Feedthroughs


Other Options
Customized box sizes
Integrating  customer’s instruments into the glovebox, like evaporator, ALD System and Spin Coater etc.
Polycarbonate Window(s)
Quick Release Window(s)
Antechamber with interlocking door
Small chamber with sliding tray
Antechamber purging  only without vacuum
Antechamber refilling from Gas cylinder instead of box
Rectangular Antechamber
Flexible shelves – adjustable up & down – adjustable back & forth
12m3/h Rotary pump
Dry scroll pump
Prompt service


Advantages

High Capacity Purifier
Rapid removal of H2O and O2 to less than 1ppm
Long intervals between regeneration cycles.


PLC Control and Color Touchscreen HMI
Automatic Purge; Circulation; Regeneration; Pressure control; User Friendly Interface.


Long Life Moisture and Oxygen Analyzers
P2O5 Moisture Sensor: Corrosion resistant, Renewable by acid-cleaning if the probe is contaminated by HF or other corrosive environmental exposure.
ZrO2 Oxygen Sensor: Solid sensor, long life, can be exposed to air without consumption.


Customize a glove box specially for your application
Our engineering team can help to turn your idea into a solution.


Stainess Steel gas pipes and connectors
All the gloveboxes has been upgrade to stainless steel pipes and connectors with much higher corrosive-proof for highly corrosive environment.

Related News
16 / 08 / 2025
How To Use A Nitrogen Glove Box

A nitrogen glove box is a sealed workspace designed to create and maintain an inert nitrogen atmosphere, allowing operators to handle sensitive materials without the risk of oxidation, moisture damage, or contamination. This specialized equipment is widely used in industries such as battery manufacturing, pharmaceuticals, semiconductor production, and advanced research laboratories. For processes involving air-sensitive or moisture-sensitive substances, using a nitrogen glove box ensures a stable environment that safeguards both product quality and operator safety.

Read More
10 / 02 / 2025
How To Deal with The High Water And Oxygen Content in The Glove Box After Regeneration?

As a widely used experimental equipment in many fields, the control of water and oxygen content inside the glove box is crucial. When the water and oxygen content in the glove box remains high after regeneration, it not only affects the accuracy and success rate of the experiment, but may also cause

Read More
20 / 08 / 2025
Why The Glove Box Needs Nitrogen Or Other Inert Gas Protection

Certain scientific and industrial experiments require environments free from oxygen, moisture, dust, and other contaminants to protect both the materials and the people conducting the work. In these sensitive and often hazardous processes, maintaining a controlled atmosphere is not just a convenience but an absolute necessity. Glove boxes provide a sealed, safe, and clean workspace where these conditions can be precisely regulated.

Read More
21 / 10 / 2025
What Is The Main Purpose of A Glove Box?

The main purpose of the glove box is to create an efficient and safe research and production environment.In today's rapidly advancing technology, laboratory and industrial production environments have increasingly high requirements for equipment. Glove box, as a device that integrates information te

Read More
16 / 10 / 2025
How To Control The Water And Oxygen Content in The Glove Box When 3D Printing High-precision Components?

3D printing technology has been widely applied in many fields such as aerospace, medical equipment, precision instruments, etc., especially in the manufacturing of high-precision components, playing an irreplaceable role. 3D printing of high-precision components requires extremely strict environment

Read More
13 / 10 / 2025
What Is The Maximum Load-bearing Capacity of The Glove Box Storage Rack?

In various fields such as scientific research, industrial production, and medical care, glove boxes are a key experimental and storage device. The internal shelves are not only used to orderly place experimental equipment, samples, or production materials, but also directly affect the safety, ease o

Read More
Get in Touch

Quick Links

Support

Product Category

Contact Us

  Add: No. 111 Tingyi Road, Tinglin Town, Jinshan District, Shanghai 201505,P.R.China
  Tel: +86 13600040923
  Email: sales.lib@mikrouna.com
Copyright © 2024 Mikrouna (Shanghai) Industrial Intelligent Technology Co., Ltd. All Rights Reserved. Sitemap