+86 13600040923        sales.lib@mikrouna.com
You are here: Home / Service / FAQ

FAQ

  • Q What is the size of a standard glove box?

    A The standard glove box size for each glove box brand is not uniform. For example, Mikrouna's standard glove box refers to a single station glove box that includes a main box body and a transition compartment. The main box body is 1220mm long, 750mm wide, and 900mm high; The transition chamber consists of a standard circular large transition chamber and a standard circular small transition chamber. The size of the standard circular large transition chamber is 600mm in length and 360mm in diameter; The dimensions of the standard circular small transition chamber are: length 300mm, diameter 150mm; If the standard glove box cannot meet the experimental requirements, Mikrouna has three glove box production factories that can customize the size, shape, and functional requirements of the glove box main body and transition compartment.
  • Q What are the methods for regenerating the purification column of the glove box?

    A The regeneration methods for glove box purification columns mainly include physical and chemical methods. The physical method decomposes and adsorbs the adsorbate from the surface of the adsorbent material by changing conditions such as temperature, pressure, and humidity. The chemical law is to achieve desorption and purification by reacting with specific gases or solvents to break the binding force between the adsorbate and the adsorbent material.
  • Q What factors affect the replacement frequency of adsorption materials for glove box purification columns?

    A The replacement frequency of the adsorption material for the glove box purification column is influenced by various factors, including usage time, workload, environmental conditions, and the quality of the adsorption material. Generally speaking, as the usage time prolongs and the workload increases, the saturation rate of the adsorbent material will gradually increase, and the frequency of replacement will correspondingly increase. In addition, high temperature and high humidity environmental conditions may accelerate the saturation of adsorbent materials, and high-quality adsorbent materials often have longer service life and higher adsorption efficiency.
  • Q What should be noted when replacing the adsorption material of the glove box purification column?

    A
    When replacing the adsorption material of the glove box purification column, the following key points should be noted:
    1. Ensure that the circulation system is turned off before replacement to ensure operational safety.
    2. Wear necessary protective equipment such as gloves, masks, and goggles to prevent adsorbent materials from scattering or flying, causing pollution and injury.
    3. Disassemble and install according to the instructions in the equipment manual or maintenance manual to ensure that the new adsorbent material can be placed correctly and function properly.
    4. After the replacement is completed, clean up the site and restart the equipment, observe the operating status to ensure everything is normal. At the same time, the replacement process should be recorded in detail, including information such as replacement time, material brand, quantity, etc., for future reference.
    5. Without professional training, Mikrouna does not recommend self replacement and can seek after-sales service from glove box suppliers.
  • Q How is the replacement cycle of organic solvent adsorbent materials determined?

    A The replacement cycle of organic solvent adsorbent materials mainly depends on factors such as the adsorption capacity of the adsorbent material, the concentration and flow rate of the organic solvent, and the temperature of the usage environment. When the adsorbent material reaches saturation or the adsorption efficiency significantly decreases, it needs to be replaced. It is generally recommended to determine whether replacement is necessary by regularly testing the adsorption performance of the adsorbent material or observing its color changes. Meanwhile, a reasonable replacement cycle can also be set based on the recommendations and usage experience provided by the glove box supplier to ensure the cleanliness of the internal environment of the glove box.
  • Q How often does the sealing strip of the glove box need to be replaced?

    A The replacement cycle of the sealing strip of the glove box usually depends on its frequency of use, environmental conditions, and the material and quality of the sealing strip. In frequent use or harsh environmental conditions, the sealing strip may age or damage faster, so it needs to be inspected and replaced more frequently. It is generally recommended to regularly (such as quarterly or semi annual) check the condition of the sealing strip. If there is aging, hardening, cracking, or damage, it should be replaced in a timely manner to ensure the sealing performance of the glove box.
  • Q How to ensure the stability of the glove box during long-term use?

    A A glove box is a laboratory equipment that can be used continuously for a long time. To ensure the long-term stability of the glove box, it is recommended to choose materials that are corrosion-resistant, heat-resistant, structurally stable, and high-strength (such as 304 stainless steel) when purchasing the glove box to adapt to various experimental environments. Secondly, during the experiment, regular maintenance should be carried out on the adsorption of the glove box gas purification system, the accuracy of water and oxygen monitoring, and the airtightness of the glove box (such as sealing strips and valves). Through these operations, it can be ensured that the glove box has good stability during long-term use.
  • Q What is the customization service for glove boxes?

    A
    Glove box customization refers to integrating some functions that meet experimental needs on the glove box body, such as:
    1. The size and shape of the glove box are customized to meet different experimental needs and scales.
    2. Install an efficient gas purification system to ensure the purity of the environment inside the glove box.
    3. Integrated temperature and humidity control system, magnifying glass, microscope, etc. to meet experimental requirements.
    4. Customized glove box services may also involve the installation of special gas detection instruments to monitor the gas composition inside the glove box, ensuring the accuracy and safety of the experiment.
    5. In addition, according to the special requirements of the experiment, the glove box can also be equipped with additional interfaces, such as power sockets, data communication ports, or special lighting facilities.
    By providing comprehensive customized services, glove box manufacturers can ensure that each device accurately matches the customer's experimental environment and operating habits, thereby improving experimental efficiency and the quality of results.